Recipe-based control
Load-cell measurement and PLC control support adjustable water, cement and additive proportions.
AUTOMATIC GROUT PLANTS
WGP1000/2×75/100PI-E
PLC-controlled grout station with a 1000 L mixer, maximum mixing capacity of 10 m³/h and two grout pumps rated at 75 L/min each at 5 MPa.
The WGP1000/2×75/100PI-E combines a high-speed mixer, circulation pump and grout pumps for cement slurry preparation and injection. Load cells and PLC control support recipe-based water, cement and additive dosing. Automatic and manual modes allow material proportions to be adjusted, with automatic configuration and replenishment of materials.





| Model | WGP1000/2×75/100PI-E |
|---|---|
| Mixer capacity | 1000 L |
| Maximum mixing capacity | 10 m³/h |
| Grout pump duty | 2 × 75 L/min at 5 MPa |
| Water/cement ratio | 0.5–1 |
| Circulation pump power | 15 kW |
| Circulation pump speed | 1800 rpm |
| Circulation flow | 1100 L/min |
| Screw feeder power | 7.5 kW |
| Screw feeder delivery | 50 t/h |
| Water pump | ISW50-160 (2.2 kW) |
| Water pump flow / head | 8.3 m³/h / 30.2 m |
| Additive pump | ISW50-125 (0.25 kW) |
| Additive pump flow / head | 2 m³/h / 10 m |
| Air compressor | VA80-3KW |
| Air compressor exhaust volume | 0.3 m³/min |
| Power supply | Three-phase 380 V, 50 Hz |
| Dimensions excluding screw feeder (L × W × H) | 3600 × 2060 × 2520 mm |
| Weight | 2820 kg |
The pump rating is reproduced as two pumps at 75 L/min each at 5 MPa. No higher-pressure duty is inferred from the model name. Overall dimensions exclude the screw feeder. Electrical cabinet and certification suitability should be confirmed for the supplied configuration.
Load-cell measurement and PLC control support adjustable water, cement and additive proportions.
Operators can choose automatic batching or manual control to suit the work sequence.
A vortex mixer rapidly disperses water and cement before slurry transfer to the grout pumps.
The system supports automatic material preparation and replenishment.
A screw feeder, water pump, additive pump and air compressor form part of the source-listed station configuration.
Cement slurry preparation and grouting for highways and railways.
Surface and underground construction requiring engineered grout injection.
Grout mixing and pumping for construction sites and mine works.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify your grout recipe, required pumping duty, site layout and available power supply when requesting a project configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY