Two-stage mortar preparation
Sand is mixed with slurry in the first agitator before transfer to the second holding agitator.
ELECTRIC MORTAR GROUT PLANTS
WGP220/300/300PI-E
Electric mortar grout station with a 220 L vortex mixer and two separate 300 L agitators. Mixer output: 4 m³/h; pump maximum output: 50 L/min; maximum pressure: 1.5 MPa.
The WGP220/300/300PI-E combines high-speed vortex slurry mixing, mortar preparation and mechanical plunger pumping. Mixed slurry enters the first agitator, where sand is added. The mortar then flows into the second agitator, which supplies the injection pump. Mixing can continue while grouting proceeds. Frequency control provides stepless adjustment of pump flow for compatible cement and mortar mixtures.



| Model | WGP220/300/300PI-E |
|---|---|
| Mixer capacity | 220 L |
| No. 1 agitator capacity | 300 L |
| No. 2 agitator capacity | 300 L |
| Mixer output | 4 m³/h |
| Mixer power | 5.5 kW |
| Mixer speed | 1450 rpm |
| Water/cement ratio | 0.5–1 |
| Cement/sand ratio | ≥1 |
| No. 1 agitator speed | 49 rpm |
| No. 1 agitator power | 1.5 kW |
| No. 2 agitator speed | 36 rpm |
| No. 2 agitator power | 1.5 kW |
| Pump type | Mechanical plunger injection pump |
| Pump maximum output | 50 L/min |
| Pump maximum pressure | 1.5 MPa |
| Pump power | 4 kW |
| Electrical supply | 380 V, 50 Hz |
| Dimensions (L × W × H) | 2350 × 1830 × 1600 mm |
| Weight | 1275 kg |
The two 300 L agitators are separate tanks with different speeds. The model number does not indicate pump output; the technical table gives 50 L/min maximum. Maximum flow and pressure are separate limits. IP56 is an enclosure protection rating and does not establish suitability for a hazardous atmosphere; confirm any project-specific electrical requirements.
Sand is mixed with slurry in the first agitator before transfer to the second holding agitator.
Frequency control provides stepless adjustment of pumping output.
The next mixing cycle can proceed while the pump supplies grout.
A squeeze handle controls mixer-to-agitator transfer.
The source states that lifting the vibrating-screen mesh stops the machine.
Motor overload protection and an IP56 electrical cabinet are source-listed features.
Mortar grouting for dams, tunnels, subways, anchors and soil nails.
Repair, foundation reinforcement, slope support and soil compaction.
Assessed underwater and coastal-foundation injection.
Roadway reinforcement, backfill and waterproof grouting.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify your slurry recipe, required pumping duty, available power supply and site layout when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY