Integrated skid
Mixer, agitator and pump share a transportable base for site installation.
ELECTRIC GROUT PLANTS
WGP400/700/320/100TPI-E
Electric colloidal grout plant with a 400 L mixer, 700 L agitator and triplex piston pump. Four source-listed duties range from 320 L/min at 2.2 MPa to 118 L/min at 10 MPa.
The WGP400/700/320/100TPI-E integrates a colloidal mixer, agitator and reciprocating grout pump on one skid. High-speed vortex mixing disperses water, cement or bentonite, after which the slurry is transferred to the agitator for holding and pumping. The electric motor drives a triplex single-acting piston pump, with selectable operating duties for different flow and pressure requirements. A squeeze switch controls transfer between mixing and agitation.




| Model | WGP400/700/320/100TPI-E |
|---|---|
| Mixer volume | 400 L |
| Agitator volume | 700 L |
| Pump pressure range | 2.2–10 MPa |
| Mixer speed | 1500 rpm |
| Agitator speed | 45 rpm |
| Agitator power | 1.5 kW |
| Pump type | Triplex single-acting reciprocating piston pump |
| Pump stroke | 110 mm |
| Cylinder diameter | 80 mm |
| Pump duty 1 — 214 cycles/min | 320 L/min at 2.2 MPa |
| Pump duty 2 — 153 cycles/min | 230 L/min at 3.6 MPa |
| Pump duty 3 — 109 cycles/min | 165 L/min at 6.2 MPa |
| Pump duty 4 — 78 cycles/min | 118 L/min at 10 MPa |
| Pump power | 30 kW |
| Maximum particle size | 5 mm |
| Dimensions (L × W × H) | 2300 × 2100 × 1880 mm |
| Weight | 1500 kg |
Each flow, pressure and pump-speed combination is a separate duty from the source table. Do not combine the 320 L/min flow with the 10 MPa pressure. Material suitability and achievable delivery depend on the grout recipe and pipeline system.
Mixer, agitator and pump share a transportable base for site installation.
High-speed vortex mixing disperses cement or bentonite slurry before holding and pumping.
Three single-acting cylinders provide grout delivery with reduced pulsation.
The technical table pairs each pump speed with a corresponding flow and pressure.
A squeeze switch selects transfer between the mixing and agitation stages.
Soil and rock grouting, permeation injection, anchors, bolts, tiebacks and soil nails.
Contact grouting, tunnel works and shaft applications.
Engineered foundation grouting, waterproofing and dam-related injection.
Suitable slurry-wall, slab-undersealing, drilling and restoration applications.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify the slurry recipe, required pumping duty, delivery distance, site conditions and available power when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY