Colloidal mixing
A high-shear circulation mixer prepares cement and additive-based grout.
ELECTRIC GROUT PLANTS
WGP200/300/100PI-E
Electric mixing and injection plant with a 200 L mixer, 300 L agitator and 60 L water tank. Mixer production: 4 m³/h at W/C = 1; pump maximum output: 100 L/min; working pressure: 10 MPa.
The WGP200/300/100PI-E combines a high-shear colloidal grout mixer, agitator and hydraulic grout pump on one base frame. It mixes cement, ultra-fine cement and compatible admixtures for anchoring, soil nailing and other engineered injection work. Prepared grout passes to a slowly agitated holding tank while pumping proceeds, supporting continuous preparation and delivery. The source describes a bag breaker and hopper, hydraulic mixture transfer and cleaning access as part of its standard configuration.




| Model | WGP200/300/100PI-E |
|---|---|
| Mixer volume | 200 L |
| Agitator volume | 300 L |
| Mixer production at W/C = 1 | 4 m³/h |
| Mixer circulation capacity | 1100 L/min |
| Suitable water/cement ratio | 0.5–1 |
| Mixer electric motor | 7.5 kW at 1450 rpm |
| Agitator speed | 36 rpm |
| Agitator electric motor | 1.5 kW at 1450 rpm |
| Grout pump model | GGH90 |
| Grout pump maximum output | 100 L/min |
| Grout pump working pressure | 10 MPa |
| Grout pump electric motor | 11 kW at 1450 rpm |
| Water tank | 60 L |
| Dimensions (L × W × H) | 2400 × 2300 × 1620 mm |
| Weight | 1320 kg |
The 1100 L/min circulation figure is not grout-pump delivery. The maximum 100 L/min output and 10 MPa working pressure are separate source-listed specifications; confirm the required operating point. Application names do not establish a complete jet-grouting or multi-component system configuration.
A high-shear circulation mixer prepares cement and additive-based grout.
A hydraulically driven vertical agitator keeps mixed grout moving during pumping.
The source specifies a Siemens motor with WEG as an option.
Schneider components are specified for the electrical control box.
A Yuken reversing valve controls the pump hydraulic system.
Butterfly valves and a linked switch control transfer; oil-temperature monitoring controls the cooler fan and over-temperature shutdown.
Continuous grout preparation for anchoring and soil-nailing projects.
Compatible slurry preparation for soil mixing, permeation grouting and bentonite work.
Grout preparation for assessed TBM annulus-backfill systems.
Mixing and pumping for suitably designed paste-backfill or cemented-rockfill projects.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify your slurry recipe, required pumping duty, available power supply and site layout when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY