Single-frame layout
The mixer, agitator and pump share a compact base frame.
ELECTRIC GROUT PLANTS
WGP300/350/85PL-E
Compact electric grout station with a 300 L mixer, 350 L agitator and hydraulic plunger pump. Pump duties: 85 L/min at 24 bar or 55 L/min at 50 bar.
The WGP300/350/85PL-E combines a mixer, agitator and hydraulic plunger grout pump on one base frame. It prepares and pumps compatible mixtures containing water, cement, sand, bentonite, filler, clay powder, silicates or other additives. Separate low- and high-pressure duties and stepless speed control support different grouting requirements.



| Model | WGP300/350/85PL-E |
|---|---|
| Mixer capacity | 300 L |
| Agitator capacity | 350 L |
| Low-pressure pump duty | 85 L/min at 24 bar |
| High-pressure pump duty | 55 L/min at 50 bar |
| Pump type | Hydraulic plunger pump |
| Mixer power | 9 kW |
| Mixer speed | 1500 rpm |
| Agitator power | 1.5 kW |
| Agitator speed | 36 rpm |
| Electrical supply | Three-phase 380 V, 50 Hz |
| Dimensions (L × W × H) | 2100 × 2030 × 1700 mm |
| Weight | 1250 kg |
The low-pressure and high-pressure ratings are separate operating duties. The 85 L/min maximum is not the output at 50 bar. Material compatibility and allowable particle size require confirmation for the selected pump and recipe.
The mixer, agitator and pump share a compact base frame.
Low- and high-pressure pumping modes support different output requirements.
The source specifies Yuken relief and directional valves for the hydraulic system.
Butterfly valves connect the mixer and agitator.
An oil-temperature gauge controls the cooler fan, with automatic shutdown if oil temperature is too high.
Soil grouting and earth-foundation stabilisation.
Waterproof grouting and tunnel-lining works.
Underwater foundations and bridge-deck work.
Deep-well casing and slope-line grouting.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify your slurry recipe, required pumping duty, available power supply and site layout when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.