Diesel hydraulic power
The source specifies a Deutz F3L912 engine for the hydraulic system.
DIESEL GROUT PLANTS
WGP200/300/100PI-D
Diesel hydraulic injection plant with a 200 L mixer, 300 L agitator and 60 L water tank. Source-listed pump output maximum: 100 L/min; working pressure: 10 MPa.
The WGP200/300/100PI-D integrates a mixer, agitator and hydraulic plunger grout pump on one base frame. It prepares compatible mixtures of water, cement, bentonite, sand, fillers, clay powder, silicates and other additives. A Deutz F3L912 diesel engine powers the plant, while linked transfer controls and butterfly valves manage movement between mixer and agitator.





| Model | WGP200/300/100PI-D |
|---|---|
| Mixer volume | 200 L |
| Agitator volume | 300 L |
| Mixer production at W/C = 1 | 4 m³/h |
| Mixer circulation capacity | 1100 L/min |
| Suitable water/cement ratio | 0.5–1 |
| Mixer hydraulic motor speed | 1450 rpm |
| Agitator hydraulic motor speed | 36 rpm |
| Water tank | 60 L |
| Grout pump model | GGH90 |
| Grout pump maximum output | 100 L/min |
| Grout pump working pressure | 10 MPa |
| Diesel engine | Deutz F3L912 |
| Engine power / speed | 34 kW at 2200 rpm |
| Dimensions (L × W × H) | 4130 × 1850 × 2500 mm |
| Weight | 2795 kg |
The 1100 L/min figure is circulation inside the mixer. Pump maximum output and working pressure are separately listed specifications; confirm the intended operating point, slurry composition and particle-size compatibility.
The source specifies a Deutz F3L912 engine for the hydraulic system.
Mixer, agitator and hydraulic grout pump share one base frame.
A Yuken reversing valve controls the grout-pump hydraulic system.
Butterfly valves and a linked switch control the mixer and agitator.
An oil-temperature gauge controls the cooler fan, with automatic shutdown on excessive temperature.
Dam foundations, tunnels, anchors, soil nails, foundation stabilisation and building or bridge restoration.
Pavement undersealing, slab jacking and slab raising.
Assessed underwater foundations, tunnel contact grouting and shaft waterproofing.
Waterproofing, slope-line grouting, well casing, sealing and abandonment.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify your slurry recipe, required pumping duty, available power supply and site layout when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY