External hydraulic drive
Uses a suitable hydraulic power source, without an electrical connection for its drive system.
HYDRAULIC GROUT PLANTS
WGP220/450/38H-H
Hydraulically driven plant with a 220 L mixer, 450 L agitator and GH32-330SR hose pump. Pump output: 19–38 L/min; pressure: 14 bar. External hydraulic supply: 45 L/min at 16.5 MPa.
The WGP220/450/38H-H integrates slurry mixing, agitation and hose-pump delivery in one modular unit. A centrifugal pump recirculates water, cement and suitable additives through the mixer. A squeeze valve then redirects the prepared slurry into the agitator, leaving the mixer free for the next batch. The hose pump delivers slurry from the agitated holding vessel. Drive power comes from an external hydraulic source, so the drive system does not require a site electrical connection.





| Model | WGP220/450/38H-H |
|---|---|
| Mixer volume | 220 L |
| Agitator volume | 450 L |
| Hose pump output | 19–38 L/min |
| Mixer speed | 1500 rpm |
| Agitator speed | 46 rpm |
| Hose pump model | GH32-330SR |
| Hose pump pressure | 14 bar |
| Required external hydraulic supply | 45 L/min at 16.5 MPa |
| Drive system | External hydraulic supply |
| Dimensions (L × W × H) | 2350 × 1030 × 1920 mm |
| Weight | 950 kg |
The required hydraulic supply is 45 L/min at 16.5 MPa; this is the drive supply requirement, not the grout delivery pressure. Hose-pump pressure is 14 bar. Confirm slurry compatibility and the external hydraulic source before selection.
Uses a suitable hydraulic power source, without an electrical connection for its drive system.
Centrifugal-pump circulation blends water, cement and compatible additives.
The 450 L agitator keeps prepared slurry moving while it awaits pumping.
A GH32-330SR pump provides the specified output and pressure.
Hydraulic valves, pressure gauges and a speed-control valve support operation and monitoring.
A squeeze valve selects recirculation in the mixer or transfer into the agitator.
Preparation and delivery of compatible cement slurry for filling and grouting.
Selected tunnel void filling and backfill operations.
Placement of pumpable cement-based slurry into accessible gaps and cavities.
Onshore or offshore filling operations where a compatible hydraulic source and site arrangement are available.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify the slurry recipe, required pumping duty, delivery distance, site conditions and available power when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY