Compact integrated layout
The high-shear mixer, rectangular agitator and grout pump share one base frame.
ELECTRIC GROUT PLANTS
WGP300/300/75PI-E
Compact electric grout plant with a 300 L high-shear mixer, 300 L rectangular agitator and hydraulically driven piston pump. Rated mixer output: 4.5 m³/h.
The WGP300/300/75PI-E integrates a mixer, rectangular agitator and piston grout pump. High-shear mixing combines water with cement or bentonite, then transfers the slurry into the agitator to maintain suspension. The hydraulically driven double-acting piston pump delivers grout with adjustable pressure and flow. A rectangular agitator reduces the overall footprint, while a ball-valve switch selects high- or low-speed pumping.





| Model | WGP300/300/75PI-E |
|---|---|
| Mixer capacity | 300 L |
| Agitator capacity | 300 L |
| Mixer output | 4.5 m³/h |
| Dimensions (L × W × H) | 2330 × 1260 × 1790 mm |
| Weight | 1125 kg |
| Mixer motor power | 7.5 kW |
| Mixer speed | 1450 rpm |
| Water/cement ratio (source notation) | ≥0.5–1 |
| Agitator speed | 36 rpm |
| Agitator motor power | 1.5 kW |
| Pump — high-speed range | 0–75 L/min; 0–5 MPa |
| Pump — low-speed range | 0–38 L/min; 0–10 MPa |
| Pump motor power | 11 kW |
| Electrical supply | 380 V, 50 Hz |
High- and low-speed ranges are separate operating modes; maximum flow and maximum pressure are not simultaneous ratings. The source gives the water/cement ratio as “≥0.5~1”; confirm the suitable recipe and electrical configuration for the intended application.
The high-shear mixer, rectangular agitator and grout pump share one base frame.
The vertical double-acting pump uses hydraulic drive and reversing.
A ball-valve switch selects high or low speed; pressure and output are steplessly adjustable.
A counter records and displays pump reciprocating cycles.
Air and water coolers support operation under different ambient conditions.
A squeeze handle controls mixer-to-agitator transfer; the agitator can be opened for cleaning.
Dam foundations, soil nails, tiebacks, earth anchors and rock bolts.
Building and bridge restoration, foundation stabilization and soil or rock grouting.
Undersealing, slab jacking and slab raising.
Grouting for underwater foundations, piers and shoreline foundations.
Tunnel lining, contact grouting, shaft waterproofing and utility encasements.
Well casing, sealing and abandonment applications.
Application areas; suitability and the grouting design require project-specific engineering assessment.
Specify the grout recipe, required flow and pressure, site conditions and available power when requesting a configuration.
Discuss your requirements ↗LET’S DISCUSS YOUR REQUIREMENTS
Material. Flow. Pressure. Power supply. Destination.
EQUIPMENT INQUIRY